nih-gov/www.ncbi.nlm.nih.gov/books/NBK482302/index.html?report=printable

127 lines
No EOL
36 KiB
XML
Raw Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" xml:lang="en" lang="en">
<head><meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<!-- AppResources meta begin -->
<meta name="paf-app-resources" content="" />
<script type="text/javascript">var ncbi_startTime = new Date();</script>
<!-- AppResources meta end -->
<!-- TemplateResources meta begin -->
<meta name="paf_template" content="" />
<!-- TemplateResources meta end -->
<!-- Logger begin -->
<meta name="ncbi_db" content="books" /><meta name="ncbi_pdid" content="book-part" /><meta name="ncbi_acc" content="NBK482302" /><meta name="ncbi_domain" content="statpearls" /><meta name="ncbi_report" content="printable" /><meta name="ncbi_type" content="fulltext" /><meta name="ncbi_objectid" content="" /><meta name="ncbi_pcid" content="/NBK482302/?report=printable" /><meta name="ncbi_app" content="bookshelf" />
<!-- Logger end -->
<title>Biliary Stenting - StatPearls - NCBI Bookshelf</title>
<!-- AppResources external_resources begin -->
<link rel="stylesheet" href="/core/jig/1.15.2/css/jig.min.css" /><script type="text/javascript" src="/core/jig/1.15.2/js/jig.min.js"></script>
<!-- AppResources external_resources end -->
<!-- Page meta begin -->
<meta name="robots" content="INDEX,FOLLOW,NOARCHIVE" /><meta name="citation_inbook_title" content="StatPearls [Internet]" /><meta name="citation_title" content="Biliary Stenting" /><meta name="citation_publisher" content="StatPearls Publishing" /><meta name="citation_date" content="2023/07/17" /><meta name="citation_author" content="Marcelle Meseeha" /><meta name="citation_author" content="Maximos Attia" /><meta name="citation_pmid" content="29493927" /><meta name="citation_fulltext_html_url" content="https://www.ncbi.nlm.nih.gov/books/NBK482302/" /><link rel="schema.DC" href="http://purl.org/DC/elements/1.0/" /><meta name="DC.Title" content="Biliary Stenting" /><meta name="DC.Type" content="Text" /><meta name="DC.Publisher" content="StatPearls Publishing" /><meta name="DC.Contributor" content="Marcelle Meseeha" /><meta name="DC.Contributor" content="Maximos Attia" /><meta name="DC.Date" content="2023/07/17" /><meta name="DC.Identifier" content="https://www.ncbi.nlm.nih.gov/books/NBK482302/" /><meta name="description" content="Obstructive jaundice is a common condition that may result from malignant or benign diseases. Before endoscopic biliary stenting, which was introduced in the early 1980s, surgery was the primary treatment for cases of biliary obstruction. Surgical options for obstructive jaundice included Whipple procedure with hepaticojejunostomy, cholecystojejunostomy, choledochojejunostomy, or other procedures according to the predisposing condition. Biliary stents are tubes made of plastic or metal to relieve obstruction in the biliary tree or to treat biliary leaks.[1][2][3]" /><meta name="og:title" content="Biliary Stenting" /><meta name="og:type" content="book" /><meta name="og:description" content="Obstructive jaundice is a common condition that may result from malignant or benign diseases. Before endoscopic biliary stenting, which was introduced in the early 1980s, surgery was the primary treatment for cases of biliary obstruction. Surgical options for obstructive jaundice included Whipple procedure with hepaticojejunostomy, cholecystojejunostomy, choledochojejunostomy, or other procedures according to the predisposing condition. Biliary stents are tubes made of plastic or metal to relieve obstruction in the biliary tree or to treat biliary leaks.[1][2][3]" /><meta name="og:url" content="https://www.ncbi.nlm.nih.gov/books/NBK482302/" /><meta name="og:site_name" content="NCBI Bookshelf" /><meta name="og:image" content="https://www.ncbi.nlm.nih.gov/corehtml/pmc/pmcgifs/bookshelf/thumbs/th-statpearls-lrg.png" /><meta name="twitter:card" content="summary" /><meta name="twitter:site" content="@ncbibooks" /><meta name="bk-non-canon-loc" content="/books/n/statpearls/article-18279/" /><link rel="canonical" href="https://www.ncbi.nlm.nih.gov/books/NBK482302/" /><link rel="stylesheet" href="/corehtml/pmc/css/figpopup.css" type="text/css" media="screen" /><link rel="stylesheet" href="/corehtml/pmc/css/bookshelf/2.26/css/books.min.css" type="text/css" /><link rel="stylesheet" href="/corehtml/pmc/css/bookshelf/2.26/css/books_print.min.css" type="text/css" /><style type="text/css">p a.figpopup{display:inline !important} .bk_tt {font-family: monospace} .first-line-outdent .bk_ref {display: inline} </style><script type="text/javascript" src="/corehtml/pmc/js/jquery.hoverIntent.min.js"> </script><script type="text/javascript" src="/corehtml/pmc/js/common.min.js?_=3.18"> </script><script type="text/javascript">window.name="mainwindow";</script><script type="text/javascript" src="/corehtml/pmc/js/bookshelf/2.26/book-toc.min.js"> </script><script type="text/javascript" src="/corehtml/pmc/js/bookshelf/2.26/books.min.js"> </script>
<!-- Page meta end -->
<link rel="shortcut icon" href="//www.ncbi.nlm.nih.gov/favicon.ico" /><meta name="ncbi_phid" content="CE8E30A07D8885310000000000FD00DB.m_5" />
<meta name='referrer' content='origin-when-cross-origin'/><link type="text/css" rel="stylesheet" href="//static.pubmed.gov/portal/portal3rc.fcgi/4216699/css/3852956/3985586/3808861/4121862/3974050/3917732/251717/4216701/14534/45193/4113719/3849091/3984811/3751656/4033350/3840896/3577051/3852958/3984801/12930/3964959.css" /><link type="text/css" rel="stylesheet" href="//static.pubmed.gov/portal/portal3rc.fcgi/4216699/css/3411343/3882866.css" media="print" /></head>
<body class="book-part">
<div class="grid no_max_width">
<div class="col twelve_col nomargin shadow">
<!-- System messages like service outage or JS required; this is handled by the TemplateResources portlet -->
<div class="sysmessages">
<noscript>
<p class="nojs">
<strong>Warning:</strong>
The NCBI web site requires JavaScript to function.
<a href="/guide/browsers/#enablejs" title="Learn how to enable JavaScript" target="_blank">more...</a>
</p>
</noscript>
</div>
<!--/.sysmessage-->
<div class="wrap">
<div class="page">
<div class="top">
<div class="header">
</div>
<!--<component id="Page" label="headcontent"/>-->
</div>
<div class="content">
<!-- site messages -->
<div class="container content">
<div class="document">
<div class="pre-content"><div><div class="bk_prnt"><p class="small">NCBI Bookshelf. A service of the National Library of Medicine, National Institutes of Health.</p><p>StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan-. </p></div></div></div>
<div class="main-content lit-style" itemscope="itemscope" itemtype="http://schema.org/CreativeWork"><div class="meta-content fm-sec"><h1 id="_NBK482302_"><span class="title" itemprop="name">Biliary Stenting</span></h1><p class="contrib-group"><h4>Authors</h4><span itemprop="author">Marcelle Meseeha</span>; <span itemprop="author">Maximos Attia</span><sup>1</sup>.</p><h4>Affiliations</h4><div class="affiliation"><sup>1</sup> Guthrie/RPH Family Residency Program</div><p class="small">Last Update: <span itemprop="dateModified">July 17, 2023</span>.</p></div><div class="body-content whole_rhythm" itemprop="text"><div id="article-18279.s1"><h2 id="_article-18279_s1_">Continuing Education Activity</h2><p>Biliary stenting refers to the insertion of stents which are tubes made of plastic or metal to relieve obstruction in the biliary tree or to treat biliary leaks. It can be used to relieve obstruction for both benign and malignant conditions of the biliary tract, while also being used for palliative treatment of advanced malignancies of the biliary tract. This activity describes the types, indications, contraindications, and treatment protocols of biliary stenting and highlights the importance of the interprofessional team in decreasing morbidity and mortality of affected patients.</p><p>
<b>Objectives:</b>
<ul><li class="half_rhythm"><div>Describe the indications and contraindications for biliary stenting.</div></li><li class="half_rhythm"><div>Explain the procedure and types of biliary stenting.</div></li><li class="half_rhythm"><div>Outline the treatment algorithm of biliary obstruction and leaks, depending on the etiology.</div></li><li class="half_rhythm"><div>Explore the role of the interprofessional team in the emergent and appropriate use of biliary stenting in improving outcomes of patients with biliary obstruction or leaks.</div></li></ul>
<a href="https://www.statpearls.com/account/trialuserreg/?articleid=18279&#x00026;utm_source=pubmed&#x00026;utm_campaign=reviews&#x00026;utm_content=18279" ref="pagearea=body&amp;targetsite=external&amp;targetcat=link&amp;targettype=uri">Access free multiple choice questions on this topic.</a>
</p></div><div id="article-18279.s2"><h2 id="_article-18279_s2_">Introduction</h2><p>Obstructive jaundice is a common condition that may result from malignant or benign diseases. Before endoscopic biliary stenting, which was introduced in the early 1980s, surgery was the primary treatment for cases of biliary obstruction. Surgical options for obstructive jaundice included Whipple procedure with hepaticojejunostomy, cholecystojejunostomy, choledochojejunostomy, or other procedures according to the predisposing condition.&#x000a0;Biliary stents are tubes made of plastic or metal to relieve obstruction in the biliary tree or to treat biliary leaks.<a class="bk_pop" href="#article-18279.r1">[1]</a><a class="bk_pop" href="#article-18279.r2">[2]</a><a class="bk_pop" href="#article-18279.r3">[3]</a></p></div><div id="article-18279.s3"><h2 id="_article-18279_s3_">Etiology</h2><p>Causes of malignant obstructive jaundice include pancreatic cancer, cholangiocarcinoma, and metastatic disease. Causes of benign obstructive jaundice include acute and chronic pancreatitis, choledocholithiasis,&#x000a0;primary sclerosing cholangitis, AIDS cholangiopathy, strictures after invasive procedures, certain parasitic infections as in Ascaris lumbricoides, Clonorchis sinensis (Chinese liver fluke), Fasciola hepatica and other liver flukes.</p></div><div id="article-18279.s4"><h2 id="_article-18279_s4_">Epidemiology</h2><p>Pancreatic cancer is the 11th most common cancer&#x000a0;and accounts for about 3% of all cancers in the United States. Cholangiocarcinoma is not as common, but it still accounts for a reasonable number of cases per year.</p></div><div id="article-18279.s5"><h2 id="_article-18279_s5_">Pathophysiology</h2><p>Pancreatic head cancer and cholangiocarcinoma result in obstructive jaundice. Although benign diseases&#x000a0;may be the cause of obstructive jaundice, they still have deleterious effects if not treated promptly, as obstructive jaundice would lead to hepatocellular dysfunction, biliary cirrhosis and increases the incidence of cholangitis.&#x000a0;</p><p>Occlusion of the biliary stent is a common complication caused by sludge in&#x000a0;plastic or metal&#x000a0;stents or by tissue overgrowth in self-expanding metal stents (SEMSs). Bacteria have the ability to deconjugate bilirubin, producing bilirubinate salt that may lead to stent occlusion.&#x000a0;To prevent bacterial adhesion, a double-layer plastic stent with no side holes and with an internal coating of perfluoroalkoxy material&#x000a0;was developed.&#x000a0;Several plastic stent models have side holes at both ends to continue drainage if the tip of the stent is clogged; however, these side holes may favor sludge formation.&#x000a0;Adding an antireflux valve or use of different coatings on stent surface are ways to avoid stent occlusion.<a class="bk_pop" href="#article-18279.r4">[4]</a><a class="bk_pop" href="#article-18279.r5">[5]</a><a class="bk_pop" href="#article-18279.r6">[6]</a></p><p>Dislodgment of the stent is another common complication as many of the covered SEMSs&#x000a0;are&#x000a0;smooth, thus causing little adherence to the bile duct walls. This complication is lessened through stents with multiple anchoring side flaps&#x000a0;and&#x000a0;with no side holes.&#x000a0;These stents with multiple side flaps are known&#x000a0;as &#x0201c;Tannenbaum&#x0201d; stents, German for "firtree."</p></div><div id="article-18279.s6"><h2 id="_article-18279_s6_">History and Physical</h2><p>Patients present with jaundice, abdominal pain, pruritus, dark urine, clay-colored stools, or with signs of infection as in cholangitis. Other conditions may be discovered on routine blood work as hyperbilirubinemia.</p></div><div id="article-18279.s7"><h2 id="_article-18279_s7_">Evaluation</h2><p>Blood work would show elevated bilirubin level and elevated alkaline phosphatase. A CT scan or MRI of the abdomen would probably show the cause and site of obstruction in the biliary tree. Magnetic resonance cholangiopancreatography (MRCP) is a noninvasive technique to evaluate the intrahepatic and extrahepatic bile ducts and the pancreatic duct.</p></div><div id="article-18279.s8"><h2 id="_article-18279_s8_">Treatment / Management</h2><p>Biliary drainage can be either&#x000a0;percutaneous transhepatic biliary drainage (PTBD) or endoscopic biliary drainage (EBD). EBD is of 2 types: external drainage which is endoscopic nasobiliary drainage (ENBD) and internal drainage which is stent placement.&#x000a0;Endoscopic drainage is superior to percutaneous drainage because of&#x000a0;less complication rate.<a class="bk_pop" href="#article-18279.r7">[7]</a><a class="bk_pop" href="#article-18279.r8">[8]</a><a class="bk_pop" href="#article-18279.r9">[9]</a></p><p>PTBD is done as an interventional radiology procedure. This access may be used in the future&#x000a0;for biliary interventions such as stone removal with a choledochoscope, placement of biliary stents, and treatment of biliary strictures. Both PTBD and ENBD have several complications and disadvantages including self-extraction, dislodgment, twisting, and collapse of the tube,&#x000a0;patient discomfort&#x000a0;and electrolyte abnormalities secondary to loss of bile and its contents. Other complications related to PTBD include bile leakage and pneumothorax. Bile cultures can be done, if needed, through these 2 approaches.&#x000a0;On the other hand, endoscopic biliary drainage has the advantage of lack of discomfort for the patient and no loss of electrolytes or fluid.</p><p>Biliary stents are made of plastic or metal.&#x000a0;Biliary sphincterotomy is not&#x000a0;required for inserting a single plastic stent or self-expanding metal stent (SEMS), but if indicated, blended electrosurgical current needs to be used. The French (Fr) is the unit of measurement of the external diameter of biliary stents and is equal to one third of a millimeter. Most standard duodenoscopes have working channels that are 4.2 mm in diameter, which makes it impossible to introduce larger plastic stents through. The&#x000a0;stent length is usually the distance between the proximal and distal flaps of the stent.</p><p>For palliation of malignant biliary obstruction, endoscopic biliary stenting carries a lower morbidity than surgery. Generally&#x000a0;speaking, SEMSs are preferred to plastic stents because of decreased incidence of stent obstruction at 4 months. Therefore, in these patients, if life expectancy is less than 4 months, plastic stents are indicated as this would be more cost-effective, especially those measuring 10 Fr in diameter. If life expectancy is longer than 4 months, SEMSs are recommended. On the other hand, if the malignant stricture is resectable, surgery within a week (to insert a plastic biliary stent for biliary drainage preparing for delayed surgery)&#x000a0;is recommended,&#x000a0;as it carries less morbidity. Preoperative drainage of potentially resectable biliary obstruction is recommended only in patients with severe itching and delayed surgery, in patients with acute cholangitis, or in patients who would undergo neoadjuvant therapies. SEMSs&#x000a0;are recommended in those patients undergoing neoadjuvant therapies.</p><p>Cholecystectomy is the most common cause of biliary leaks, and biliary stenting can be used to treat these leaks. In acute cholangitis, endoscopic sphincterotomy with stone extraction and/or stent insertion is the treatment of choice for biliary drainage. Stents can also help with management of refractory choledocholithiasis.</p><p>Early complications of biliary stenting include infection, bleeding, and pancreatitis. Complications of biliary stents include occlusion caused by sludge in both types&#x000a0;of stents&#x000a0;or by tissue overgrowth in SEMS.&#x000a0;Dislodgment happens more frequently at 20% of the time with fully covered SEMSs, followed by plastic stents and partially covered SEMSs approximately 5% of the time. This complication is not as frequent with uncovered SEMSs with a rate of 1%.&#x000a0;Dislodgment happens with benign biliary strictures more often than with malignant strictures.</p><p>Plastic biliary stents differ in length, diameter, shape, material, and price. They range from 1&#x000a0;to 25 cm&#x000a0;in length, but standard models range from 5 to 18 cm. Longer models&#x000a0;are used in liver transplant patients.&#x000a0;They range&#x000a0;from 3&#x000a0;to 11.5 Fr in diameter. Standard external diameters of plastic biliary stents are 7.0, 8.5, 10.0, and 11.5 Fr. They can be straight, curved, wedge, angled, winged, with single or double pigtail (rarely used), and with center bend and/or duodenal bend. Wedge stents have no flaps. Other stents have flaps which can be external or internal, with single,&#x000a0;two or&#x000a0;four flaps, to prevent dislocation.&#x000a0;S-shaped plastic stents are particularly designed to drain the left biliary tree.&#x000a0;The stents are made up of polyethylene (most common), polyurethane, polyethylene/polyurethane blend, Teflon or soft polymer blend.&#x000a0;Some types of stents&#x000a0;are made of an inner layer of Perfluoro, a middle layer of stainless steel and an outer layer of polyamide elastomer.&#x000a0;European Society of Gastrointestinal Endoscopy (ESGE) recommends against Teflon stents as&#x000a0;they&#x000a0;are not as soft as Polyethylene stents.</p><p>Likewise, SEMSs have different lengths, diameters, designs, delivery systems, and materials. Length of the stents ranges from 4&#x000a0;to 12 cm. Diameters, when expanded, range from 6&#x000a0;to 10 mm. The delivery system ranges from 6.5 Fr to 8.5 Fr, done through an outer sheath, and is withdrawn after placing the stent in the duct, allowing the stent to expand.&#x000a0;SEMSs have different designs: hook and cross, hand woven, laser cut, and&#x000a0;some have a retrieval loop, that helps with repositioning or retrieval of the stent after placement. SEMSs may be uncovered, partially covered, or fully covered SEMSs. Coverings include silicone, polyether polyurethane, polyurethane, polytetrafluoroethylene fluorinated ethylene propylene, or polycaprolactone. Coverings allow easier extraction of stents after being inserted, an advantage which uncovered stents lack because of tumor ingrowth or benign tissue hyperplasia. All SEMSs are radiopaque as they&#x000a0;are made up of metal alloys most commonly nitinol which is a combination of nickel and titanium. This is the metal of choice because it can conform to the lumen. Other metal components include stainless steel or platinol which is platinum core with nitinol encasement. These metals allow for conformability to the duct along with adequate radial expansile force. Generally&#x000a0;speaking, metal stents are more expensive than plastic stents, and hence, the preference for plastic stents in patients with life expectancy less than 4 months. However, despite their higher initial cost,&#x000a0;SEMSs are associated with a statistically significant lower incidence of occlusion, less therapeutic failure, thus less need for endoscopic reintervention, decreased length of hospital stay, and lower cholangitis incidence.&#x000a0;Thereby, SEMSs would eventually decrease use of many medical resources and reduce overall health cost.</p><p>
<b>Technique of Stent Insertion</b>
</p><p>Materials required for plastic stent insertion include radiopaque guidewire, stent insertion system and dilators. The guide wire most often has a stiffer shaft and a hydrophilic tip to make passage of strictures easier. Guidewire systems have a locking mechanism to prevent the wire from slipping during exchange procedures. They may have intraductal exchange that allows for removing the catheter while leaving the guide wire in the biliary tract, thus insertion of multiple plastic stents would be feasible. Stent insertion system consists of a plastic guiding catheter (with radiopaque markers), stent, and pusher tube. A guiding catheter is not required for 7 Fr stents. A balloon catheter or bougie is used to overcome a stricture.</p><p>The required stent length is assessed based on cholangiography and should be the shortest possible that allows adequate drainage. One end of the stent should be 1 to 2 cm beyond the proximal biliary obstacle and the other end should be 1 cm into the duodenum. If the intraduodenal portion of the stent is long, perforation or bleeding ulcer may happen. The stent is loaded onto the guiding catheter, which is flushed with saline. The stent insertion system is introduced into the working channel of the duodenoscope. The guiding catheter is then disconnected from the pusher tube after going past the stricture and the stent is progressively inserted. Stent insertion is made easier through anticlockwise rotation and pulling of the endoscope. The endoscope has to be near the papilla throughout the procedure to avoid looping of the insertion system in the duodenum. When the stent is in the proper position, the guide wire and the guiding catheter are withdrawn leaving the pusher tube in contact with the stent to prevent dislocation. An X-ray is obtained to verify patency. The upper end of the stent should be below the cystic duct. Long plastic stents can be shortened by a snare wire of a lithotripter. Insertion of SEMS is done under fluoroscopy. Long SEMSs may be trimmed using argon plasma coagulation.</p><p>New stents that need further investigation include antireflux stents, drug-eluting stents, bioabsorbable stents, and magnetic stents. Magnetic stents have been investigated and tested in animals where the stent can be retrieved using a magnet held from outside the body, thus obviating the need for a second ERCP to remove the stent. The concern was with the possibility that the stent may migrate proximally.</p></div><div id="article-18279.s9"><h2 id="_article-18279_s9_">Differential Diagnosis</h2><ul><li class="half_rhythm"><div>Alcoholic hepatitis</div></li></ul><ul><li class="half_rhythm"><div>Ampullary carcinoma</div></li></ul><ul><li class="half_rhythm"><div>Ascariasis</div></li></ul><ul><li class="half_rhythm"><div>Bile duct strictures</div></li></ul><ul><li class="half_rhythm"><div>Bile dust tumors</div></li></ul><ul><li class="half_rhythm"><div>Biliary disease</div></li></ul><ul><li class="half_rhythm"><div>Biliary trauma</div></li></ul><ul><li class="half_rhythm"><div>Cholangiocarcinoma</div></li></ul><ul><li class="half_rhythm"><div>Cholangitis</div></li></ul><ul><li class="half_rhythm"><div>Cholecystitis</div></li></ul></div><div id="article-18279.s10"><h2 id="_article-18279_s10_">Enhancing Healthcare Team Outcomes </h2><p>Biliary stenting has become a very&#x000a0;useful treatment for biliary drainage. In the majority of instances, biliary stents are used to manage obstructive jaundice from either a benign or malignant cause. The biliary stents are usually implanted by gastroenterologists and interventional radiologist. However, healthcare workers who look after patients with jaundice should be aware of stenting as an option for treatment and can be life-saving. Despite advances in stent manufacture, stenosis of stents is a recurring problem, necessitating removal and replacement. Some studies indicate that covered stents have a higher patency compared to bare stents. Other studies show that metal covered stents work well but are associated with higher rates of pancreatitis compared to uncovered metal stents.<a class="bk_pop" href="#article-18279.r10">[10]</a><a class="bk_pop" href="#article-18279.r11">[11]</a><a class="bk_pop" href="#article-18279.r12">[12]</a></p></div><div id="article-18279.s11"><h2 id="_article-18279_s11_">Review Questions</h2><ul><li class="half_rhythm"><div>
<a href="https://www.statpearls.com/account/trialuserreg/?articleid=18279&#x00026;utm_source=pubmed&#x00026;utm_campaign=reviews&#x00026;utm_content=18279" ref="pagearea=body&amp;targetsite=external&amp;targetcat=link&amp;targettype=uri">Access free multiple choice questions on this topic.</a>
</div></li><li class="half_rhythm"><div>
<a href="https://mdsearchlight.com/gut-health/biliary-stenting/?utm_source=pubmedlink&#x00026;utm_campaign=MDS&#x00026;utm_content=18279" ref="pagearea=body&amp;targetsite=external&amp;targetcat=link&amp;targettype=uri">Click here for a simplified version.</a>
</div></li><li class="half_rhythm"><div>
<a href="https://www.statpearls.com/articlelibrary/commentarticle/18279/?utm_source=pubmed&#x00026;utm_campaign=comments&#x00026;utm_content=18279" ref="pagearea=body&amp;targetsite=external&amp;targetcat=link&amp;targettype=uri">Comment on this article.</a>
</div></li></ul></div><div id="article-18279.s12"><h2 id="_article-18279_s12_">References</h2><dl class="temp-labeled-list"><dt>1.</dt><dd><div class="bk_ref" id="article-18279.r1">Ahmad J. Metal, magnet or transplant: options in primary sclerosing cholangitis with stricture. <span><span class="ref-journal">Hepatol Int. </span>2018 Nov;<span class="ref-vol">12</span>(6):510-519.</span> [<a href="https://pubmed.ncbi.nlm.nih.gov/30430358" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 30430358</span></a>]</div></dd><dt>2.</dt><dd><div class="bk_ref" id="article-18279.r2">Huespe PE, Oggero S, de Santiba&#x000f1;es M, Boldrini G, D Agostino D, Pekolj J, de Santiba&#x000f1;es E, Ciardullo M, Hyon SH. Percutaneous Patency Recovery and Biodegradable Stent Placement in a Totally Occluded Hepaticojejunostomy After Paediatric Living Donor Liver Transplantation. <span><span class="ref-journal">Cardiovasc Intervent Radiol. </span>2019 Mar;<span class="ref-vol">42</span>(3):466-470.</span> [<a href="https://pubmed.ncbi.nlm.nih.gov/30420998" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 30420998</span></a>]</div></dd><dt>3.</dt><dd><div class="bk_ref" id="article-18279.r3">Lee JH, Ahmed O. Endoscopic Management of Pancreatic Cancer. <span><span class="ref-journal">Surg Oncol Clin N Am. </span>2019 Jan;<span class="ref-vol">28</span>(1):147-159.</span> [<a href="https://pubmed.ncbi.nlm.nih.gov/30414679" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 30414679</span></a>]</div></dd><dt>4.</dt><dd><div class="bk_ref" id="article-18279.r4">Ciambella CC, Beard RE, Miner TJ. Current role of palliative interventions in advanced pancreatic cancer. <span><span class="ref-journal">World J Gastrointest Surg. </span>2018 Oct 27;<span class="ref-vol">10</span>(7):75-83.</span> [<a href="/pmc/articles/PMC6212542/" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pmc">PMC free article<span class="bk_prnt">: PMC6212542</span></a>] [<a href="https://pubmed.ncbi.nlm.nih.gov/30397425" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 30397425</span></a>]</div></dd><dt>5.</dt><dd><div class="bk_ref" id="article-18279.r5">Siiki A, Vaalavuo Y, Antila A, Ukkonen M, Rinta-Kiikka I, Sand J, Laukkarinen J. Biodegradable biliary stents preferable to plastic stent therapy in post-cholecystectomy bile leak and avoid second endoscopy. <span><span class="ref-journal">Scand J Gastroenterol. </span>2018 Oct-Nov;<span class="ref-vol">53</span>(10-11):1376-1380.</span> [<a href="https://pubmed.ncbi.nlm.nih.gov/30394150" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 30394150</span></a>]</div></dd><dt>6.</dt><dd><div class="bk_ref" id="article-18279.r6">Petrone MC, Archibugi L, Forti E, Conigliaro R, Di Mitri R, Tarantino I, Fabbri C, Larghi A, Testoni SGG, Mutignani M, Arcidiacono PG. Novel lumen-apposing metal stent for the drainage of pancreatic fluid collections: An Italian multicentre experience. <span><span class="ref-journal">United European Gastroenterol J. </span>2018 Nov;<span class="ref-vol">6</span>(9):1363-1371.</span> [<a href="/pmc/articles/PMC6206530/" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pmc">PMC free article<span class="bk_prnt">: PMC6206530</span></a>] [<a href="https://pubmed.ncbi.nlm.nih.gov/30386609" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 30386609</span></a>]</div></dd><dt>7.</dt><dd><div class="bk_ref" id="article-18279.r7">Zhang X, Wang X, Wang L, Tang R, Dong J. Effect of covered self-expanding metal stents compared with multiple plastic stents on benign biliary stricture: A meta-analysis. <span><span class="ref-journal">Medicine (Baltimore). </span>2018 Sep;<span class="ref-vol">97</span>(36):e12039.</span> [<a href="/pmc/articles/PMC6133465/" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pmc">PMC free article<span class="bk_prnt">: PMC6133465</span></a>] [<a href="https://pubmed.ncbi.nlm.nih.gov/30200083" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 30200083</span></a>]</div></dd><dt>8.</dt><dd><div class="bk_ref" id="article-18279.r8">Rao HB, Prakash A, Sudhindran S, Venu RP. Biliary strictures complicating living donor liver transplantation: Problems, novel insights and solutions. <span><span class="ref-journal">World J Gastroenterol. </span>2018 May 21;<span class="ref-vol">24</span>(19):2061-2072.</span> [<a href="/pmc/articles/PMC5960812/" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pmc">PMC free article<span class="bk_prnt">: PMC5960812</span></a>] [<a href="https://pubmed.ncbi.nlm.nih.gov/29785075" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 29785075</span></a>]</div></dd><dt>9.</dt><dd><div class="bk_ref" id="article-18279.r9">Teoh AYB, Dhir V, Kida M, Yasuda I, Jin ZD, Seo DW, Almadi M, Ang TL, Hara K, Hilmi I, Itoi T, Lakhtakia S, Matsuda K, Pausawasdi N, Puri R, Tang RS, Wang HP, Yang AM, Hawes R, Varadarajulu S, Yasuda K, Ho LKY. Consensus guidelines on the optimal management in interventional EUS procedures: results from the Asian EUS group RAND/UCLA expert panel. <span><span class="ref-journal">Gut. </span>2018 Jul;<span class="ref-vol">67</span>(7):1209-1228.</span> [<a href="https://pubmed.ncbi.nlm.nih.gov/29463614" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 29463614</span></a>]</div></dd><dt>10.</dt><dd><div class="bk_ref" id="article-18279.r10">Teng F, Xian YT, Lin J, Li Y, Wu AL. Comparison of Unilateral With Bilateral Metal Stenting for Malignant Hilar Biliary Obstruction. <span><span class="ref-journal">Surg Laparosc Endosc Percutan Tech. </span>2019 Feb;<span class="ref-vol">29</span>(1):43-48.</span> [<a href="https://pubmed.ncbi.nlm.nih.gov/30418421" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 30418421</span></a>]</div></dd><dt>11.</dt><dd><div class="bk_ref" id="article-18279.r11">Yuan T, Zhu Y, Wang X, Cui W, Cao J. Efficacy and safety evaluation of paclitaxel-loaded metal stents in patients with malignant biliary obstructions. <span><span class="ref-journal">Eur J Surg Oncol. </span>2019 May;<span class="ref-vol">45</span>(5):816-819.</span> [<a href="https://pubmed.ncbi.nlm.nih.gov/30389299" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 30389299</span></a>]</div></dd><dt>12.</dt><dd><div class="bk_ref" id="article-18279.r12">Cassani LS, Chouhan J, Chan C, Lanke G, Chen HC, Wang X, Weston B, Ross WA, Raju GS, Lee JH. Biliary Decompression in Perihilar Cholangiocarcinoma Improves Survival: A Single-Center Retrospective Analysis. <span><span class="ref-journal">Dig Dis Sci. </span>2019 Feb;<span class="ref-vol">64</span>(2):561-569.</span> [<a href="https://pubmed.ncbi.nlm.nih.gov/30238201" ref="pagearea=cite-ref&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">PubMed<span class="bk_prnt">: 30238201</span></a>]</div></dd></dl></div><div><dl class="temp-labeled-list small"><dt></dt><dd><div><p class="no_top_margin">
<b>Disclosure: </b>Marcelle Meseeha declares no relevant financial relationships with ineligible companies.</p></div></dd><dt></dt><dd><div><p class="no_top_margin">
<b>Disclosure: </b>Maximos Attia declares no relevant financial relationships with ineligible companies.</p></div></dd></dl></div></div></div>
<div class="post-content"><div><div class="half_rhythm"><a href="/books/about/copyright/">Copyright</a> © 2025, StatPearls Publishing LLC.<p class="small">
This book is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
(<a href="https://creativecommons.org/licenses/by-nc-nd/4.0/" ref="pagearea=meta&amp;targetsite=external&amp;targetcat=link&amp;targettype=uri">
http://creativecommons.org/licenses/by-nc-nd/4.0/
</a>), which permits others to distribute the work, provided that the article is not altered or used commercially. You are not required to obtain permission to distribute this article, provided that you credit the author and journal.
</p></div><div class="small"><span class="label">Bookshelf ID: NBK482302</span><span class="label">PMID: <a href="https://pubmed.ncbi.nlm.nih.gov/29493927" title="PubMed record of this page" ref="pagearea=meta&amp;targetsite=entrez&amp;targetcat=link&amp;targettype=pubmed">29493927</a></span></div></div></div>
</div>
</div>
</div>
<div class="bottom">
<div id="NCBIFooter_dynamic">
<!--<component id="Breadcrumbs" label="breadcrumbs"/>
<component id="Breadcrumbs" label="helpdesk"/>-->
</div>
<script type="text/javascript" src="/portal/portal3rc.fcgi/rlib/js/InstrumentNCBIBaseJS/InstrumentPageStarterJS.js"> </script>
</div>
</div>
<!--/.page-->
</div>
<!--/.wrap-->
</div><!-- /.twelve_col -->
</div>
<!-- /.grid -->
<span class="PAFAppResources"></span>
<!-- BESelector tab -->
<noscript><img alt="statistics" src="/stat?jsdisabled=true&amp;ncbi_db=books&amp;ncbi_pdid=book-part&amp;ncbi_acc=NBK482302&amp;ncbi_domain=statpearls&amp;ncbi_report=printable&amp;ncbi_type=fulltext&amp;ncbi_objectid=&amp;ncbi_pcid=/NBK482302/?report=printable&amp;ncbi_app=bookshelf" /></noscript>
<!-- usually for JS scripts at page bottom -->
<!--<component id="PageFixtures" label="styles"></component>-->
<!-- CE8B5AF87C7FFCB1_0191SID /projects/books/PBooks@9.11 portal107 v4.1.r689238 Tue, Oct 22 2024 16:10:51 -->
<span id="portal-csrf-token" style="display:none" data-token="CE8B5AF87C7FFCB1_0191SID"></span>
<script type="text/javascript" src="//static.pubmed.gov/portal/portal3rc.fcgi/4216699/js/3879255/4121861/3501987/4008961/3893018/3821238/3400083/3426610.js" snapshot="books"></script></body>
</html>