Multicenter Study on Incubation Conditions for Environmental Monitoring and Aseptic Process Simulation
- PMID: 27593691
- DOI: 10.5731/pdajpst.2016.006791
Multicenter Study on Incubation Conditions for Environmental Monitoring and Aseptic Process Simulation
Abstract
Environmental monitoring and aseptic process simulations represent an integral part of the microbiological quality control system of sterile pharmaceutical products manufacturing operations. However, guidance documents and manufacturers practices differ regarding recommendations for incubation time and incubation temperature, and, consequently, the environmental monitoring and aseptic process simulation incubation strategy should be supported by validation data. To avoid any bias coming from in vitro studies or from single-site manufacturing in situ studies, we performed a collaborative study at four manufacturing sites with four samples at each location. The environmental monitoring study was performed with tryptic soy agar settle plates and contact plates, and the aseptic process simulation study was performed with tryptic soy broth and thioglycolate broth. The highest recovery rate was obtained with settle plates (97.7%) followed by contact plates (65.4%) and was less than 20% for liquid media (tryptic soy broth 19% and thioglycolate broth 17%). Gram-positive cocci and non-spore-forming Gram-positive rods were largely predominant with more than 95% of growth and recovered best at 32.5 °C. The highest recovery of molds was obtained at 22.5 °C alone or as the first incubation temperature. Strict anaerobes were not recovered. At the end of the five days of incubation no significant statistical difference was obtained between the four conditions. Based on these data a single incubation temperature at 32.5 °C could be recommended for these four manufacturing sites for both environmental monitoring and aseptic process simulation, and a second plate could be used, periodically incubated at 22.5 °C. Similar studies should be considered for all manufacturing facilities in order to determine the optimal incubation temperature regime for both viable environmental monitoring and aseptic process simulation.
Lay abstract: Microbiological environmental monitoring and aseptic process simulation confirm that pharmaceutical cleanrooms are in an appropriate hygienic condition for manufacturing of sterile drug products. Guidance documents from different health authorities or expert groups differ regarding recommendation of the applied incubation time and incubation temperature, leading to variable manufacturers practices. Some recent publications have demonstrated that laboratory studies are not relevant to determine the best incubation regime and that in situ manufacturing site studies should be used. To solve any possible bias coming from laboratory studies or single-site in situ studies, we conducted a multicenter study at four manufacturing sites with a significant amount of real environmental monitoring samples collected directly from the environment in pharmaceutical production during manufacturing operations with four solid and liquid nutrient media. These samples were then incubated under four different conditions suggested in the guidance documents. We believe that the results of our multicenter study confirming recent other single-site in situ studies could be the basis of the strategy to determine the best incubation regime for both viable environmental monitoring and aseptic process simulation in any manufacturing facility.
Keywords: Aseptic process simulation; Cleanroom; Environmental monitoring; Incubation conditions; Incubation temperature; Microbiology; Primary isolation of microorganisms.
© PDA, Inc. 2017.
Similar articles
-
Comparison of different incubation conditions for microbiological environmental monitoring.PDA J Pharm Sci Technol. 2014 Sep-Oct;68(5):394-406. doi: 10.5731/pdajpst.2014.00994. PDA J Pharm Sci Technol. 2014. PMID: 25336415
-
Media-fill simulation tests in manual and robotic aseptic preparation of injection solutions in syringes.J Oncol Pharm Pract. 2016 Apr;22(2):195-204. doi: 10.1177/1078155214565123. Epub 2014 Dec 30. J Oncol Pharm Pract. 2016. PMID: 25549919
-
Examination of the order of incubation for the recovery of bacteria and fungi from pharmaceutical-grade cleanrooms.Int J Pharm Compd. 2014 May-Jun;18(3):242-7. Int J Pharm Compd. 2014. PMID: 25306772
-
Increasing Patient Safety by Closing the Sterile Production Gap-Part 3-Moist Heat Resistance of Bioburden.PDA J Pharm Sci Technol. 2017 Jul-Aug;71(4):274-278. doi: 10.5731/pdajpst.2017.007641. Epub 2017 Apr 17. PDA J Pharm Sci Technol. 2017. PMID: 28416646 Review.
-
Choosing a Vial Processing Line for Aseptic Compounding: Part 1.Int J Pharm Compd. 2016 Jul-Aug;20(4):283-292. Int J Pharm Compd. 2016. PMID: 28333673 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources