Application of real-time cell electronic sensing (RT-CES) technology to cell-based assays
- PMID: 15357917
- DOI: 10.1089/adt.2004.2.363
Application of real-time cell electronic sensing (RT-CES) technology to cell-based assays
Abstract
Label-free detection emerges as a new approach in the development of technologies for cell-based screening assays. Unlike the classic detection methods that use fluorescence, radioisotope, luminescence, or light absorption, label-free detection directly measures the cell function without using a labeled molecule. The advantages of label-free detection include a simple homogeneous assay format, noninvasive measurement, less interference with normal cell function, kinetic measurement, and reduced time for assay development. Here, we have applied the electrical impedance detection method in a real-time cell electronic sensing (RT-CES trade mark ) system for cell-based assays. The cell growth rate measured by this RT-CES system was comparable to actual cell number counted manually. In addition, cell proliferation, cytotoxicity, cytoprotection, cell growth inhibition, and apoptosis data generated by this RT-CES system correlated with those determined by the classic methods. The conclusion is that the RT-CES system is a useful tool for label-free detection of certain cell-based parameters.
Similar articles
-
Dynamic and label-free cell-based assays using the real-time cell electronic sensing system.Assay Drug Dev Technol. 2006 Oct;4(5):597-607. doi: 10.1089/adt.2006.4.597. Assay Drug Dev Technol. 2006. PMID: 17115930 Review.
-
Dynamic monitoring of cytotoxicity on microelectronic sensors.Chem Res Toxicol. 2005 Feb;18(2):154-61. doi: 10.1021/tx049721s. Chem Res Toxicol. 2005. PMID: 15720119
-
A cell-microelectronic sensing technique for profiling cytotoxicity of chemicals.Anal Chim Acta. 2008 May 12;615(1):80-7. doi: 10.1016/j.aca.2008.03.047. Epub 2008 Apr 1. Anal Chim Acta. 2008. PMID: 18440366
-
Dynamic detection of natural killer cell-mediated cytotoxicity and cell adhesion by electrical impedance measurements.Assay Drug Dev Technol. 2006 Oct;4(5):555-63. doi: 10.1089/adt.2006.4.555. Assay Drug Dev Technol. 2006. PMID: 17115926
-
Cellular impedance biosensors for drug screening and toxin detection.Analyst. 2007 Sep;132(9):835-41. doi: 10.1039/b704513a. Epub 2007 Jun 26. Analyst. 2007. PMID: 17710258 Free PMC article. Review.
Cited by
-
Impedance responses reveal β₂-adrenergic receptor signaling pluridimensionality and allow classification of ligands with distinct signaling profiles.PLoS One. 2012;7(1):e29420. doi: 10.1371/journal.pone.0029420. Epub 2012 Jan 5. PLoS One. 2012. PMID: 22242170 Free PMC article.
-
Celastrol inhibits pathologic neovascularization in oxygen-induced retinopathy by targeting the miR-17-5p/HIF-1α/VEGF pathway.Cell Cycle. 2022 Oct;21(19):2091-2108. doi: 10.1080/15384101.2022.2087277. Epub 2022 Jun 13. Cell Cycle. 2022. PMID: 35695424 Free PMC article.
-
Rap1 GTPase activation and barrier enhancement in rpe inhibits choroidal neovascularization in vivo.PLoS One. 2013 Sep 10;8(9):e73070. doi: 10.1371/journal.pone.0073070. eCollection 2013. PLoS One. 2013. PMID: 24039860 Free PMC article.
-
Real-time monitoring of flavivirus induced cytopathogenesis using cell electric impedance technology.J Virol Methods. 2011 May;173(2):251-8. doi: 10.1016/j.jviromet.2011.02.013. Epub 2011 Feb 22. J Virol Methods. 2011. PMID: 21349291 Free PMC article.
-
Impedance-based analysis of Natural Killer cell stimulation.Sci Rep. 2018 Mar 21;8(1):4938. doi: 10.1038/s41598-018-23368-5. Sci Rep. 2018. PMID: 29563530 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources