Implementation of metrological traceability in laboratory medicine: where we are and what is missing
- PMID: 32069227
- DOI: 10.1515/cclm-2019-1128
Implementation of metrological traceability in laboratory medicine: where we are and what is missing
Abstract
Background The Joint Committee on Traceability in Laboratory Medicine (JCTLM) has recently created the Task Force on Reference Measurement System Implementation (TF-RMSI) for providing guidance on traceability implementation to in vitro diagnostics (IVD) manufacturers. Using serum creatinine (sCr) as an example, a preliminary exercise was carried out by checking what type of information is available in the JCTLM database and comparing this against derived analytical performance specifications (APS) for measurement uncertainty (MU) of sCr. Content APS for standard MU of sCr measurements were established as a fraction (≤0.75, minimum quality; ≤0.50, desirable quality; and ≤0.25, optimum quality) of the intra-individual biological variation of the measurand (4.4%). By allowing no more than one third of the total MU budget for patient samples to be derived from higher-order references, two out of the four JCTLM reference materials (RMs) at least allow minimum APS to be achieved for the MU of patient samples. Commutability was explicitly assessed for one of the JCTLM-listed matrixed RMs, which was produced in compliance with ISO 15194:2009 standard, whereas the remaining three RMs were assessed against the ISO 15194:2002 version of the standard, which only required the extent of commutability testing to be reported. Regarding the three listed reference methods, the MU associated with isotopic dilution-mass spectrometry coupled to gas chromatography (ID/GC/MS) and isotopic dilution-mass spectrometry coupled to liquid chromatography (ID/LC/MS) would allow APS to be fulfilled, while the isotope dilution surface-enhanced Raman scattering (ID/SERS) method displays higher MU. Summary The most recently listed RM for sCr in the JCTLM database meets the ISO 15194:2009 requirements with MU that would allow APS to be fulfilled and has had commutability demonstrated for use as a common calibrator in implementing traceability of sCr measurements. Splitting clinical samples with a laboratory performing ID/GC/MS or ID/LC/MS provides an alternative but would also require all components of uncertainty of these materials to be assessed. Outlook Using appropriately derived APS to judge whether reference measurement system components are fit for purpose represents a novel approach. The TF-RMSI is planning to review a greater number of measurands to provide more robust information about the state of the art of available reference measurement systems and their impact on the ability of clinical measurements to meet APS.
Keywords: creatinine; measurement uncertainty; metrological traceability; standardization.
Similar articles
-
Optimizing Available Tools for Achieving Result Standardization: Value Added by Joint Committee on Traceability in Laboratory Medicine (JCTLM).Clin Chem. 2021 Nov 26;67(12):1590-1605. doi: 10.1093/clinchem/hvab178. Clin Chem. 2021. PMID: 34633037
-
Feasibility of Metrological Traceability Implementation Using the Joint Committee on Traceability in Laboratory Medicine Database Entries Including the Fulfillment of "Fit-for-Purpose" Maximum Allowable Measurement Uncertainty.Clin Chem. 2024 Nov 4;70(11):1321-1333. doi: 10.1093/clinchem/hvae131. Clin Chem. 2024. PMID: 39316470
-
Sources and performance criteria of uncertainty of reference measurement procedures.Clin Biochem. 2018 Jul;57:29-36. doi: 10.1016/j.clinbiochem.2018.05.018. Epub 2018 May 29. Clin Biochem. 2018. PMID: 29856964
-
The role of analytical performance specifications in international guidelines and standards dealing with metrological traceability in laboratory medicine.Clin Chem Lab Med. 2024 Apr 8;62(8):1462-1469. doi: 10.1515/cclm-2023-1201. Print 2024 Jul 26. Clin Chem Lab Med. 2024. PMID: 38579121 Review.
-
The utility of measurement uncertainty in medical laboratories.Clin Chem Lab Med. 2020 Mar 3;58(9):1407-1413. doi: 10.1515/cclm-2019-1336. Print 2020 Aug 27. Clin Chem Lab Med. 2020. PMID: 32126011 Review.
Cited by
-
Determination of calcium, iron, and selenium in human serum by isotope dilution analysis using nitrogen microwave inductively coupled atmospheric pressure plasma mass spectrometry (MICAP-MS).Anal Bioanal Chem. 2024 May;416(13):3117-3125. doi: 10.1007/s00216-024-05274-0. Epub 2024 Apr 8. Anal Bioanal Chem. 2024. PMID: 38589614 Free PMC article.
-
Evaluation of the Comparability of Wantai Wan200+ Instrument with Routine Laboratory Assays for 21 Different Analytes.J Clin Med. 2024 Apr 12;13(8):2246. doi: 10.3390/jcm13082246. J Clin Med. 2024. PMID: 38673517 Free PMC article.
-
Estimation of the measurement uncertainty and practical suggestion for the description of the metrological traceability in clinical laboratories.Biochem Med (Zagreb). 2021 Feb 15;31(1):010501. doi: 10.11613/BM.2021.010501. Epub 2020 Dec 15. Biochem Med (Zagreb). 2021. PMID: 33380886 Free PMC article. Review.
-
Determination of lithium in human serum by isotope dilution atomic absorption spectrometry.Anal Bioanal Chem. 2022 Jan;414(1):251-256. doi: 10.1007/s00216-021-03636-6. Epub 2021 Sep 10. Anal Bioanal Chem. 2022. PMID: 34505166 Free PMC article.
-
Advances in D-dimer testing: progress in harmonization of clinical assays and innovative detection methods.Anal Bioanal Chem. 2024 Jul;416(16):3737-3750. doi: 10.1007/s00216-024-05207-x. Epub 2024 Mar 20. Anal Bioanal Chem. 2024. PMID: 38503987 Review.
References
-
- Braga F, Panteghini M. Verification of in vitro medical diagnostics (IVD) metrological traceability: responsibilities and strategies. Clin Chim Acta 2014;432:55–61.
-
- Panteghini M. Implementation of standardization in clinical practice: not always an easy task. Clin Chem Lab Med 2012;50:1237–41.
-
- Braga F, Infusino I, Panteghini M. Performance criteria for combined uncertainty budget in the implementation of metrological traceability. Clin Chem Lab Med 2015;53:905–12.
-
- Pasqualetti S, Braga F, Panteghini M. Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results. Clin Biochem 2017;50:587–94.
-
- Infusino I, Panteghini M. Measurement uncertainty: friend or foe? Clin Biochem 2018;57:3–6.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous