Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2007 Jan;35(1):106-11.
doi: 10.1097/01.CCM.0000251128.60336.FE.

High-frequency oscillatory ventilation following prone positioning prevents a further impairment in oxygenation

Affiliations
Randomized Controlled Trial

High-frequency oscillatory ventilation following prone positioning prevents a further impairment in oxygenation

Didier Demory et al. Crit Care Med. 2007 Jan.

Abstract

Objective: The improvement in oxygenation with prone positioning is not persistent when patients with acute respiratory distress syndrome (ARDS) are turned supine. High-frequency oscillatory ventilation (HFOV) aims to maintain an open lung volume by the application of a constant mean airway pressure. The aim of this study was to show that HFOV is able to prevent the impairment in oxygenation when ARDS patients are turned back from the prone to the supine position.

Design: Prospective, comparative randomized study.

Setting: A medical intensive care unit.

Patients: Forty-three ARDS patients with a Pao2/Fio2 ratio <150 at positive end-expiratory pressure > or =5 cm H2O.

Interventions: After an optimization period, the patients were assigned to one of three groups: a) conventional lung-protective mechanical ventilation in the prone position (12 hrs) followed by a 12-hr period of conventional lung-protective mechanical ventilation in the supine position (CV(prone)-CV(supine)); b) conventional lung-protective mechanical ventilation in the supine position (12 hrs) followed by HFOV in the supine position (12 hrs) (CV(supine)-HFOV(supine)); or c) conventional lung-protective mechanical ventilation in the prone position (12 hrs) followed by HFOV in the supine position (CV(prone)-HFOV(supine) group).

Measurements and main results: Pao2/Fio2 ratio was higher at the end of the study period in the CV(prone)-HFOV(supine) group than in the CV(prone)-CV(supine) group (p < .02). Venous admixture at the end of the study period was lower in the CV(prone)-HFOV(supine) group than in the two other groups.

Conclusions: HFOV maintained the improvement in oxygenation related to prone positioning when ARDS patients were returned to the supine position.

PubMed Disclaimer

Comment in

  • ARDS--shake, rattle, and roll!
    Lapinsky SE, Mehta S. Lapinsky SE, et al. Crit Care Med. 2007 Jan;35(1):303-4. doi: 10.1097/01.CCM.0000251845.70488.2D. Crit Care Med. 2007. PMID: 17197775 Review. No abstract available.

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources