* Rewrite much of the execution of meraki_switchport
- Previous versions had problems with idempotency and allowed_vlans
* Modified payload creation
- Parameter map is used
- propsed is created using .copy()
- Much cleaner this way
* Add whitespace for lint
* Add bugfix snippet for changelog
* Adding Support For EVPN in BGP Module
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Fix Pep8 Failures in onyx_bgp.py
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Fix Pep8 Failures in onyx_bgp.py Phase 2
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Fix Samer's Comments
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Remove file Variable
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Adding Support for NVE Protocol in onyx_protocol
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Fix Pep8 Failures in onyx_protocol.py
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Adding Support for Traffic Class in Onyx Switches
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Enhancing the code and elemenating code duplicate
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* nxos_vpc:Fix idempotency issues with multiple attributes
Several attributes were causing idempotency problems on various platforms:
- `auto_recovery`
- This command can be disabled on certain platforms and will nvgen as `no auto-recovery`
- When enabled it has an additional optional-keyword for changing the `reload-delay` timer value
- This was addressed by adding a new attribute `auto_recovery_reload_delay` to handle setting the timer value
- This new attribute is mutually exclusive with `auto_recovery`
- `/show run vpc/show run vpc all/`
- Changed the command that gets state to `all` so that it could differentiate between `auto-recovery` and `auto-recovery reload-delay`
- This change resulted in also changing some attribute handling withing `get_vpc`, since some attributes like `peer_gw` relied on presence of the config to determine state true or false. With `all` the config is always there so these attrs must specifically check for `'no '` in the string.
- `delay_restore`
- This command has two additional, optional keywords that exist on some platforms and not others.
- New attrs:
- `delay_restore_interface_vlan`
- `delay_restore_orphan_port`
- Modified the `sanity` test to include the new attributes and to fix the platform issues.
- Bugfix Pull Request
`modules/network/nxos/nxos_vpc.py`
- Validated `nxos_vpc` `sanity` test on these platforms, all are now 100% Pass: N35, N3K, N3K-F, N6K, N7K, N9K, N9K-F
- TBD: Future work is needed to add support for `peer_gw_exclude_gw` timers. This could be addressed in the same way as the `auto_recovery_reload_delay` changes included here.
* lint fix
* Add 'version_added' tags for new options
* nxos_snmp_user: platform fixes for get_snmp_user
snmp user output behavior varies quite a bit for the different nxos platforms and required several workarounds:
- N5K/N6k
- These platforms do not support structured output for `show snmp user`.
- The current code lands in an `except` clause when the output is not structured; so I added a new `get_non_structured_snmp_user` method to scrape the state from the regular cli output if it's present.
- N9K-F
- The `group` data in the JSON output is different for this platform; it has a different key (just `group` instead of `TABLE_groups` or `group_names`) and it is not indexed
- For a single group the value is a string, for multiple groups it's a list
- sanity
- N5K/N6K/N9K-F platforms will reject `no snmp user <name> <role>` when it's the last role defined for the user.
- workaround is to use `nxos_user` to remove the user
- Changes validated on:
- `N3K, N3K-F, N35, N6K, N7K, N9K, N9K-F`
- `6.0(2)A8`
- `7.0(3)I2, 7.0(3)I4, 7.0(3)I5, 7.0(3)I6, 7.0(3)I7`
- `7.3(2)D1`
- `7.3(3)N1, 7.3(4)N1`
- `8.3(2)`
- `9.2(2), 9.2(3)`
* fix lint warning
* Alter tests to pass
* Change diff_against to make changed work again
* Add another diff_against
* Expose supports_sessions across all EOS connection types
* Change session warning to failure
* supports_sessions needs to be a method to survive the rpc boundary
* Alter tests to match
The ACI MultiSite PATCH API has a deficiency requiring some objects to be referenced by index.
This can cause silent corruption on concurrent access when changing/removing on object as
the wrong object may be referenced.
This PR removes some references by index, and documents this issue for
others.
* nxos_snmp_traps: fix 'group: all' for N35 platforms
- `group: all` attempts to enable traps for all features defined in the module's `feature_list`
- `N35` platforms do not support `snmp-server enable traps bfd`; so removing `bfd` from the `feature_list` for that platform
- Minor cleanup in `sanity.yaml` test file
* whitespace lint fix
* Fixes Netconf_config single parameter bug
Fixes 56022
fixed get_config to not require multiple parameters to just run a backup
* Add Integration test for netconf_config
Associated with #56022
tests backup through netconf only using one parameter.
* Added debug to the begin and end of file
* Fix formatting of save config. #56022
* removed blank line at end: #56022
The `nxos_vlan` module may raise with regex error `sre_constants.error: multiple repeat` in the non_structured codepath if the device has existing vlan names with certain regex control characters; e.g.
```
VLAN Name Status Ports
---- -------------------------------- --------- -------------------------------
1 default active Eth1/3
14 my-vlan-name-is-*** active
```
* `nxos_acl` may fail with `IndexError: list index out of range` while attempting to delete a non-existent ACL.
The failure occurs when the `acl` var is an empty list.
* nxos_acl: catch 501 'Structured output unsupported' when no ACLs present
With some older image versions, `show ip access-list | json` will raise a 501 error indicating `'Structured output unsupported'` when there are no access-lists configured. This change turns off the `check_rc` and then looks for the failure condition.
* Fix kwarg
* Fix lint issues
* Make module not get all nets every time it's executed with net_id
* Add changelog fragment
* Update changelogs/fragments/meraki_static_route_api_calls.yml
Co-Authored-By: kbreit <kevin.breit@kevinbreit.net>
* Update ce.py
while to_text(out, errors='surrogate_then_replace').strip().endswith(']'):
display.vvvv('wrong context, sending exit to device', self._play_context.remote_addr)
conn.exec_command('return')
out = conn.get_prompt()
connetion has no send_command function and ce device has no 'exit' command to return user-view(a correct context),but 'return' .command.
* Add files via upload
Some bugs fix.
* Add files via upload
fix some bugs
* fix a bug for ce_command
Running a command with prompt via ce_command, It doesn't work.The reason is that the key word for network_cli recognition is answer not response.
* fix bugs
fix bugs for ce modules
* Update ce.py
* Delete ce_ftp.py
need modify
* Delete ce_lacp.py
* Add files via upload
* Delete ce_aaa_server.py
* Delete ce_aaa_server_host.py
* Compatible with Python 3
Compatible with Python 3 and fix bugs for ce
* Update ce_aaa_server.py
* Add files via upload
modify doc
* Add files via upload
Compatible with Python 3 and fix bugs
* Add files via upload
Compatible with Python 3 and fix bugs
* Add files via upload
Cancellation of change
* Update ce_netconf.py
It is a bug that response has no xml attribute:line 183
* Add files via upload
* Add files via upload
Compatible with Python 3 and fix bugs
* updatp ce_config.py
a bug for this module.
* Remove code but leave the metadata so that they can be listed as
removed in documentation.
* Remove removed modules from validate-modules ignore
* Remove unittests for the removed nodules
* Remove links to removed modules and add list of removed moduels to the
2.9 porting guide
* Adding Support For Vxlan In Onyx Switches
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Fix Pep8 Failures in onyx_vxlan.py
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Fix Pep8 Failures in onyx_vxlan phase 2
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Fix Shippable failures
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Fix Samer's Comments on PR
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Adding New Model for Configure Buffer Pool on Onyx Switches
Signed-off-by: Anas Badaha <anasb@mellanox.com>
* Fix Pep8 Failures in onyx_buffer_pool.py
Signed-off-by: Anas Badaha <anasb@mellanox.com>